Low
pressure air circuit breaker
Fixed and withdrawing AE-SS frame breaker can choose from AE630--SS
to AE6300--SS, 3Por 4P with current 630A to 6300A. There are 6 kinds
free adjusting currents for every spec current. The safe module
increased 30% breaking ability than common breaker. It has no arc
space and its complete function can satisfy different needs. The
price is cheaper comparing with coordinative plinkucts in the market.
VPR
vacuum breaker
VPR vacuum breaker has simple structure. three-dimensional CAD
and CAE design increase the breaker security. It has good insulating
capability, easy maintenance, various spec and miniaturization that
can be adopted for various projects. The pressure is 3.6-12KV. The
current is 630A-3150A. The breaking ability is 25KA、31.5KA、40KA
that can be selected.
Plastic shell breaker
The improved super plastic shell breaker has high performance,
complete variety and is easy to use.The new-style ETR ensures accurate
protection for the circuit. 30-800A PSS has five sizes, two faceplates
that can be selected.MCCB Plastic shell breaker:
| NF-CP economic type |
NF-SP normal type |
| NF-UP ultra currentlimiting
type |
MB motor breaker type |
| ELCB creepage breaker:NV-CP economic
type,NV-SP normal type,NV-UP ultra currentlimiting type,MN motor
breaker type |
| MCB small beaker:BH series BH-P series BH-S
series BH-PS series BH-D eries |
| The current is from 3A-4000A that can
be selected for various projects. |
Magnetic contactor and motor starter
S- N series contactor
MS-N new series contactor(S-N10~S-N800)is
safe and easy to install. It has quick connection mode, simple and
easy inspection, reliable contact head. It's suitably used for the
current 10A-1000A and matching for 4KW-500KW的 three-phase electric
machine.
TH type hot relay
TH-N
series hot relay provides convenient and safe electric protection,
easy maintaining and inspection. The rated current is easy to adjust.
The standard finger protection has automatic and manual replacement.
TH-N12、TH-N20、TH-N20TA、TH-N60、TH-N60TA、TH-N120、TH-N120TA、TH-N220、TH-N400、TH-N600
series. The current setting range is 0.2-800A.
Current switchboard uses new plinkuct
"DIN series"

The whole series achieved CCIB、CCEE authentication,satisfied
GB、IEC authentication,satisfied GB、IEC standard.The standard IEC35M
creepage breaker adopts Sanling original special IC that ensures
creepage protection.
| MCB plastic shell breaker BH-D6 1P、2P、3P、4P、rating
current6-63A |
| RCCB creepage breaker BV-D 2P、4P、rating
current 25A、40A、63A |
| ISOLATING SWITCH isolated switch KB-D 1P、2P、3P、4P
rating current 32A、63A。 |
|